Run an accountability check with saved settings

Procedure

  1. With the two structures that you want to compare open in structure views, select the appropriate levels and choose Tools→Accountability Check→Accountability Check.

  2. Verify that the correct structures are listed in the Source objects and Target objects boxes. If necessary, add structures by selecting them and clicking .

  3. In the Available Settings box, select the entry that includes the appropriate settings for the accountability check.

Only the settings applicable to the types of structures that you selected as source and target are displayed in the Available Settings list.

  1. Click OK.

Teamcenter runs the accountability check and lists the results in the Accountability Check view.

  1. Examine the results and make the necessary modifications to the structures.

  2. Rerun the check using the same settings by clicking in the Accountability Check view.

Note

How far you need to expand the structure depends on the settings in place when the saved setting was created. Ask your administrator for information about how far to expand the selected structures.

When running an accountability check based on saved settings or rerunning an accountability check, you cannot report the results in occurrence groups or create a printable report. Consider running an asynchronous accountability check.

Related Topics

  • Save accountability check settings

  • Types of structures you can compare and propagate