Configuring structures by occurrence effectivity
Associate existing effectivity to an occurrence
Note
Use this approach only when you want the effectivity to be the same for all occurrences sharing this effectivity object. If you edit the effectivity object's date or unit number ranges, Teamcenter applies this change to all occurrences that reference it.
Procedure
Select the line in the structure representing the occurrence with which you want to associate effectivity.
Choose Tools→Effectivity→Occurrence Effectivity→View, Create and Edit.Teamcenter opens the Occurrence Effectivity dialog box.
In the Effectivity ID box, type the identifier of the effectivity object you want to associate with the occurrence, and press the Enter key. Alternatively, you can search for the effectivity object by clicking Search adjacent to the Effectivity ID box.Teamcenter populates the date or unit number table with the ranges from the effectivity object.
Click OK and Teamcenter associates the effectivity with the occurrence.