ManufacturingKnowledge

Configuring studies

Set up study synchronization

You must set up the study synchronization rules before publishing or synchronizing a study.

Note

You must have DBA privileges to perform this task.

The synchronization rules are set up using a combination of object type and property that are to be considered.

Procedure

  1. Choose Advanced→Study Synchronization Rules.

  2. Select the synchronization mode.

Event-Based Performs a partial synchronization or publish of only the selected properties.

Time-Based Performs a full synchronization or publish.

  1. Select the direction in which the changes are synchronized.

Select To Study to set up synchronization changes from the source process structure to the study.

Select From Study to set up publish changes from the study to the source process structure.

  1. Choose whether to include or exclude the properties you select in the list.

To exclude properties from synchronization:

Select Exclude the following properties. Include the rest.

Press Ctrl and select the object type and property name of each property you do not want to include.

Tip To perform a full Time-Based synchronization, select Exclude the following properties and remove all entries from the properties list.

To include properties in synchronization:

Select Include the following properties.

Select the object type and property name.

Click Add.

Click each newly highlighted cell and open the list of entries by clicking the down arrow.

Select the desired object type and property name. Tip To synchronize children of selected structures, select the object type and the Mfg0sub_elements property.

  1. Click Save.

Teamcenter saves the settings in study preferences. You do not need to modify these preferences manually. Note You can set up custom synchronization rules by adding modes to the Mfg0SimStudyRuleMode global list of values (LOV) in the Business Modeler IDE. By default, this LOV contains only Time-Based and Event-Based entries. Your new mode is then displayed in the Manage Synchronization Rules dialog box, and you can create corresponding synchronization and publish rules for the custom mode.