Administering Resource Manager
Store the machining data library in Teamcenter
You can store feeds and speeds data in the database in Teamcenter where it is managed instead of in the ASCII library in NX. The data is retrievable from the classification hierarchy.
Procedure
Install the required classes using the manufacturing resource library installer.
Convert the NX ASCII files into SML files using the mrm_migrate_machining_data utility.For example:Copy
mrm_migrate_machining_data -u=user-id -p=password -g=group-root_dir=d:\NX9.0\MACH\\resource\library\feeds_speeds\ascii\Import the SML files using the smlutility utility.For example:Copy
smlutility -import -u=user-id -p=password -g=group -file=migrated_machining_data.sml -update
Source: https://docs.sw.siemens.com/en-US/doc/282219420/PL20251212545240207.resource_mgr/xid959100 · retrieved 2026-07-11